• wer

Cardiopulmonary resuscitation model 300

Cardiopulmonary resuscitation model 300

Short Description:

 


Product Detail

Product Tags

Product Introduction:
This model is designed according to international CPR standards to simulate the real phenomenon of resuscitation of cardiac arrest patients. It is automatically controlled by computer and can simulate chest compressions,
Artificial respiration, carotid artery automatic pulsation, heart automatic recovery of pulsation sound, pupil from dilation automatic reduction to normal. The operation is correct or not, there are photoelectric
Signal display, digital display, timing display, language display, score printing, etc. It has dynamic sensibility and authenticity for simulated rescue training of rescue personnel.
The shape is novel and vivid, the function is complete and practical. In fact, it is ideal for mass health rescue training, cardiopulmonary resuscitation training, teaching and assessment in hospitals and health schools at all levels
Model.
Main product parameters:
1. The new cardiopulmonary resuscitation training products that implement the 2020 cardiopulmonary resuscitation standards have obvious anatomical characteristics and real feel.
2. Simulated vital signs: In the initial state, simulated human pupil dilation, carotid artery no pulsation. During the pressing process, simulate the passive pulsation of human carotid artery and pulse frequency
Consistent with the pressure frequency. After successful rescue, the simulated human pupil returned to normal, the carotid artery beat autonomously, artificial respiration and cardiac compression could be performed, and the airway could be opened.
3. Three modes of operation: CPR training, simulation assessment, method one: CPR training, you can press and blow. Method two: Assessment mode, in regulation
Within the specified time, according to the 2020 International cardiopulmonary resuscitation standards, press and blow 30:2 ratio, complete 5 cycle operations, with the display press correctly counted
The number is 30, 60, 90, 120, 150, and the correct number of blowing is 2, 4, 6, 8, 10. Mode three: Combat mode, within the specified time according to 2020 country
International cardiopulmonary resuscitation standard, press and blow 30:2 ratio, complete 5 cycle operations, with the display press correct and wrong counts of 30, 60,
90, 120, 150, blowing correct and wrong counts add up to 2, 4, 6, 8, 10.
4. Electronic monitoring: electronic monitoring of airway opening and pressing parts. Show the correct and incorrect number of breaths and compressions.
5. Voice prompt: The whole Chinese voice prompt during training and assessment can be turned on and off, and the volume of the section can be investigated.
6. Bar code display blowing capacity: the correct blowing capacity is 500/600ml-1000ml: when the blowing capacity is too small, the bar code is yellow. When blown properly, strip shape
The code is green.
7. The bar code shows the pressing depth. When the pressing depth is too small, the bar code is yellow. The bar code is green when the press depth is appropriate.
8. Score printing: Operation results can be thermally printed transcripts;
9. The operation time can be set, in seconds.
10. Operating frequency: greater than or equal to 100 times/min.
Packing: 1 piece/box, 94x38x58cm, 21kgs
Standard set configuration:
One advanced cardiopulmonary resuscitation simulator; One advanced digital tube display;
Luxury hand-push human body hard plastic box; A resuscitation operation pad; Disposable disinfection mask (50 sheets/box) 1 box; Five lung bags can be changed;
Two volumes of thermal printing paper; One set of product warranty card, product certificate, operation manual and first aid operation manual.


  • Previous:
  • Next:

  • Write your message here and send it to us